ASTM C1262 PDF

ASTM C1262 PDF

The following summarizes the contents of ASTM C and key components of the test methods used to determine relative freeze thaw durability. This does not. ASTM C Standard Test Method for Evaluating the Freeze-Thaw The following summarizes the contents of ASTM C and key components of the test. Buy ASTM C Standard Test Method for Evaluating the Freeze-Thaw Durability of Manufactured Concrete Masonry Units and Related Concrete Units.

Author: Nezil Fetaxe
Country: Bermuda
Language: English (Spanish)
Genre: Music
Published (Last): 1 April 2008
Pages: 468
PDF File Size: 7.98 Mb
ePub File Size: 18.84 Mb
ISBN: 851-7-16858-907-3
Downloads: 12055
Price: Free* [*Free Regsitration Required]
Uploader: Mazahn

The testing laboratory performing this test method should be evaluated in accordance with Practice C However, other means could be used to obtain similar architectural effects like tumbling, grinding, and slumping. Open containers to visually inspect the condition of the specimens and to adjust the test solution level to comply with 7. Each specimen shall bemarked with a unique identification number on the non-molded surface of the specimen.

Some values have only SI units because the inch-pound equivalents are not used in practice. Consider any pieces that separated from the specimen as part of the residue.

Immediately following saw-cutting, remove zstm particles and residue from the coupon by rinsing in tap water and brushing with a soft bristle brush. Report these values for each specimen as well as the average of the specimens tested.

Rinse the residue from specimens tested in saline solution three times with water to remove any soluble salt. Related concrete units include units such as hollow and solid concrete masonry units, concrete brick, and concrete roof pavers. Historical Version s – ast, previous versions of standard.

  BS1192 PART 5 PDF

Product Specifications

Cut the coupon from the exposed surface of the unit as the unit is used in service unless the exposed surface is an architectural or other nonplanar surface see Note 6. In the case of a unit with an exposed architectural or other nonplanar surface, cut the coupon from another flat molded surface ideally as far as possible from the architectural or other nonplanar face and in no case less than 2 in.

Link to Active This link will always route to the current Active version of the standard. Note 6 – Split-faced surfaces are the most common surfaces used to provide an architectural appearance to segmental retaining walls. Do not saw-cut test specimens from units that have been previously oven dried. Do not pour test solution directly onto the specimen.

Referenced Documents purchase separately The documents listed c262 are referenced within the subject standard but are not provided as part of the standard. Using fingertips and a squeeze bottle, remove loose particles from all surfaces of the specimen, again being atm to collect all rinse water or saline solution and loose particles in the specimen container.

The following summarizes the contents of ASTM C and key c12662 of the test methods used to determine relative freeze thaw durability. Work Item s – proposed revisions of this standard.

A copy of the full standard is available upon request. This summary attempts to provide the information which is most commonly used, but Allan Block does not claim that all information contained in the standard is represented. Where the coupon thickness is less than 1. Immediately rinse the specimen with water if the specimen is tested in saline solution, use saline solutiontorinse the specimen usinga squeeze bottle,being careful to collect in the specimen container the rinse water or saline solution and all loose particles from the specimen.

  CASO CLINICO BLASTOMICOSIS PDF

Remove a single specimen from its container. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Replace the specimen in the container. Do not subject test specimens to oven-drying prior to completion of asstm testing.

ASTM C Standard Specification for Segmental Retaining Wall Units

Close the container lid tightly and store the container on a level surface in laboratory air as defined in 6. Related concrete units include units such as hollow and solid concrete masonry units, concrete brick, and concrete roof pavers. The units shall be free atsm visible cracks or structural defects. Combining values from the two systems may result in non-conformance with this standard. This does not provide a comparison to field performance but a systematic approach to testing.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Do not fully immerse coupons in water. Remove the specimen from the container, pourthe rinse water or saline solution through the filter paper, and rinse the specimen container until all residue spall in the specimen container is collected on the filter paper.

Pour the test solution from the specimen container through the filter paper to collect the residue spall from the test specimen.