¼” screws at four jamb corners – screws bending corners screws bending. – tearing in frame wall at connections pushing limits of ASTM F □ Minimal. ASTM F Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with. Mullion/Frame Design – Allowable Stress Design. ▫ Design Load = Equivalent 3 second design load ASTM F ▫ Info Required –. ▫ 1) Level of Protection.

Author: Meztirg Sharn
Country: Djibouti
Language: English (Spanish)
Genre: Education
Published (Last): 4 September 2006
Pages: 483
PDF File Size: 2.76 Mb
ePub File Size: 17.43 Mb
ISBN: 442-7-30922-578-3
Downloads: 40335
Price: Free* [*Free Regsitration Required]
Uploader: Vur

Use of the annealed or heat strengthened glass plies will also reduce the amount of load transferred into the structure. This standard was published by ASTM F14 which is a committee specializes about on systems products and services. The width of silicone or glazing tape is referred to as bite and is shown and discussed in Guide C The main keywords to present this standard are air blast pressure, blast resistant glazing, explosion, insulating glass, and laminated glass. Blast testing has awtm that use of fully tempered glass plies, when fractured during a blast event, have poorer post blast performance than annealled or heat strengthened glass plies.

ASTM F is a standard practice for specifying an equivalent 3-Second Duration design loading for blast resistant glazing fabricated with laminated glass.

The fasteners that attach the framing system that supports the glazing to the structural framing system shall be designed to resist a uniform load acting on the blast resistant glazing that has a magnitude of atsm least:. The width of silicone or glazing tape is referred to as bite and is shown and discussed in Guide C The fasteners that attach the framing system that supports the glazing satm the structural framing system shall be designed to resist a uniform load acting on the f2248 resistant glazing that has a magnitude of at least: It is the responsibility of the user of this standard to establish appropriate safety and adtm practices and determine the applicability of regulatory limitations prior to use.

ASTM F 2248

The system shall be designed to ensure that the glazing fails prior to the framing system that supports the glazing and its attachment to the structural framing system.

  A DEFENSE OF RELIGIOUS EXCLUSIVISM ALVIN PLANTINGA PDF

As a minimum, insulating glass shall use laminated glass for the inboard protected side lite. Laminated glass fabricated with fully tempered glass plies has a tendency to leave the supporting glazing system frame after satm whereas laminated glass fabricated with annealed or heat strengthened glass plies will remain in the frame and absorb remaining load through tensile membrane behavior. The width of glazing tape shall be at least equal to two times but not more than four times the thickness designation of the glass to which it adheres.

Values given in parentheses are for information only. Values given in parentheses are for information only.

Active view current version of standard. Retrieved from ” https: Glass plies used to construct laminated glass are recommended to be either annealed or heat strengthened glass.

The width of glazing tape shall be asrm least equal to two times but not more than four times the thickness designation of the glass to which it adheres. Link to Active This link will always route to the current Active version of the standard.

ASTM F – Wikipedia

This page was last edited on 28 Marchat ASTM International which was funded inis an international standards developing organization that develops and publishes standards for a wide range of materials, products, systems, and services.

Historical Version s – view previous versions of standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part f22248 the standard.

Link to Active This link will always route to the current Active version of the standard. Blast testing has shown that use of fully tempered glass plies, when fractured during a blast event, have poorer post blast performance than annealled or heat strengthened glass plies.

Work Item s – proposed revisions of this standard. By using this site, you agree to the Terms of Use and Privacy Policy. Work 2f248 s – proposed revisions of this standard. The system shall be designed to ensure that the glazing fails prior to the framing system that supports the glazing and its attachment asrm the structural framing system. Laminated glass fabricated with fully tempered glass plies has a tendency ashm leave the supporting glazing system frame after fracture whereas laminated glass fabricated with annealed or heat strengthened glass plies will remain in the frame and absorb remaining load through tensile membrane behavior.

  GRAUPNER TURBOMAT 7 PLUS PDF

ASTM F2248 – 12

As a minimum, insulating glass shall use laminated glass for the inboard protected side lite. The standard explain different methods to check the thickness and type of blast resistant glazing fabricated with laminated glass to glaze a fenestration The main keywords to present this standard are air blast pressure, blast resistant glazing, explosion, insulating glass, and laminated glass.

The fasteners that attach the framing system that supports the glazing to the structural framing system shall be designed to resist a uniform load acting on the blast resistant glazing that has a magnitude of at least: Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. From Wikipedia, the free encyclopedia.

The fasteners that attach the framing system that supports the glazing to the structural framing system shall be designed to resist a uniform load acting on the blast resistant glazing that has a magnitude of at least:. The standard explain different methods to check the thickness and type of blast resistant glazing fabricated with laminated glass to glaze a fenestration. Use of the annealed or heat atsm glass plies will also reduce the amount of load transferred into v2248 structure.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Glass plies used to construct laminated glass are recommended to be either annealed or heat strengthened glass. Views Read Edit View history.