BS EN 61439-1 PDF

BS EN 61439-1 PDF

date BS EN is withdrawn and BS EN and BS EN In addition IEC and IEC have been amended, clarified and. For each type of electrical AssEMBLY only two parts of the standard are necessary to determine all requirements: the basic standard IEC “ General rules. What changes does BS EN bring? • New testing procedure including design and routine verification. • Alternative testing routes. • Clear requirements for.

Author: Dalrajas JoJokora
Country: Romania
Language: English (Spanish)
Genre: Love
Published (Last): 22 January 2014
Pages: 330
PDF File Size: 1.64 Mb
ePub File Size: 3.84 Mb
ISBN: 460-1-40359-967-7
Downloads: 11486
Price: Free* [*Free Regsitration Required]
Uploader: Kell

Industrial locations are in addition characterised by the existence of eb or more of the following: The rated impulse withstand voltage for a given rated operational voltage shall not be less than that corresponding in Annex G to the nominal voltage of the supply system of the circuit at the point where the ASSEMBLY is to be used and the appropriate overvoltage category. In all other cases the EMC requirements are to be verified by tests as per J.

Scope of the standard

As an alternative the original manufacturer shall provide data on the suitability of materials from the insulating material supplier to demonstrate compliance with the requirements of 8. Where appropriate, routine verification shall confirm that design verification is available.

Busbar trunking systems to supersede IEC NOTE This measure is intended to prevent the appearance of dangerous voltage on the accessible parts of electrical equipment through a fault in the basic insulation.

Switchgear, disconnectors, switch-disconnectors and fuse-combination units IEC For undated references, the latest edition of the referenced document including any amendments applies. The value of the short-circuit current shall be the same as that for the main busbars. A busbar insulator or support or cable restraint has not separated into two or more pieces.

  ASISTOLIA DEFINICION PDF

Scope of the standard – IEC – Siemens

Users of British Stan-BSI provides a wide range of information on national, Europeandards should make sure that they possess the latest amendments or editions. It presents the UK view on standards in Europe and at the international level.

The data used, calculations made and comparison undertaken shall be recorded. 16439-1 fuses are installed the original manufacturer shall state the type and rating of the fuse-links to be used. The groups as defined by the original manufacturer shall be formed in a manner so that the highest possible temperature rise is obtained.

British Standards

An ASSEMBLY used or tested under installation conditions may have connections, the type, nature and disposition of which will not een the same as those adopted for the test, and a different temperature rise of terminals may result and may be required or accepted. The use of an electrically heated cabinet is recommended.

Ensembles d’appareillage Teil 2: For more explanation see Unless otherwise agreed between the ASSEMBLY manufacturer and the user, terminals for protective conductors shall allow the connection of copper conductors having a cross-section depending on the cross-section of the corresponding phase conductors according to Table 5. Moderate condensation should be borne in mind which may occasionally occur due to variations in temperature. The cross-section of the leads to these resistors shall be such that no appreciable amount of heat is conducted away from the enclosure.

Any convenient value of the test voltage may be used to produce the desired current. PE conductor provided for purposes of safety, for example protection against electric shock [IEV 611439-1 flames — Needle-flame test method — Apparatus, confirmatory test arrangement and guidance Licensed Copy: Principles, requirements and tests IEC Where an empty enclosure in accordance with IEC is used, and it has not been modified so as to degrade the performance of the enclosure, no repetition of the enclosure testing to The environments encompassed are residential, commercial and light-industrial locations, both indoor and outdoor.

  JACKSON ELETTRODINAMICA CLASSICA PDF

They are intended to protect skilled or instructed persons but are not intended to protect ordinary persons. Because the actual local temperatures of the current-carrying parts cannot be calculated by these methods, some limits and safety margins are necessary and are included. 16439-1

In accordance with the details of this clause, the actual lifts we have performed on site do represent these sequences: This standard does not apply to individual devices and self-contained components, such as motor starters, fuse switches, electronic equipment, etc.

Additionally after the tests of To shorten the test, if the devices allow it, the current may be increased during the first part of the test, it being reduced to the specified test current afterwards. Verification shall be made using a resistance measuring instrument which is capable of driving a current of at least 10 A a. It presents the UK view on standards in Europe and at the international level.