CIERRE DE COMUNICACION INTERAURICULAR PDF

CIERRE DE COMUNICACION INTERAURICULAR PDF

Request PDF on ResearchGate | Cierre de la comunicación interauricular con dispositivo oclusor implantado mediante cateterismo cardíaco | Since King and. PDF | La comunicación interauricular (CIA) es uno de los defectos congénitos que se Cierre de comunicacion interauricular por cateterismo. Presentamos nuestra experiencia inicial en cierre de la comunicación interauricular (CIA) por vía derecha, comparándola con esternotomía media. Entre julio.

Author: Nizshura Fetaur
Country: Guyana
Language: English (Spanish)
Genre: Technology
Published (Last): 25 October 2012
Pages: 130
PDF File Size: 4.6 Mb
ePub File Size: 17.58 Mb
ISBN: 466-1-64608-550-5
Downloads: 38347
Price: Free* [*Free Regsitration Required]
Uploader: Nejind

Comunicación interauricular (para Niños)

Transvenous closure of moderate and large secundum atrial septal defects in adults using the Amplatzer septal occluder. To simplify this classification we refer to Table 1. The evaluation of the IVC rim is fundamental Figure 8Bbecause PTC would be very challenging in its absence, 14 it is, however, usually the most diffcult to visualize and measure, and retrofexion of the probe may help when it is not visible in the standard bi-caval view.

Several authors have referred to these edges with anatomical connotations and others with spatial connotations. For reasons of clarity, anatomic connotations are used herein. Follow up The presence of residual shunts should be reassessed; this could be achieved with contrast echocardiography with agitated normal saline, which opacifies the right sided cardiac chambers and may demonstrate the un-opacified jet of the left to right shunt.

This serious complication can be prevented by pushing back the structure using a second catheter.

Congenital heart disease in a cohort of 19, births with long-term follow-up. Catheter Cardiovasc Interv ; Measurement of the ASD rims It is critical to recognize the nomenclature and understand the anatomical disposition of the rims or edges bordering the ASD Figure 2. Am J Cardiol ; Familiarization with TEE in this context is essential for the echocardiographer involved in the modern care of patients with Intrauricular.

Diagnosis and classification of atrial septal aneurysm by two-dimensional echocardiography: TEE assessment of ASD includes evaluation of the number and localization of the defect sdimensions and adequacy of the rims, direction and severity of the shunt, and the presence of possible associated defects.

  KOHLER K-8905 PDF

In these cases, the atrial septal defect, functioning as an over-fow, may mask the presence of left ventricular diastolic dysfunction by an enhanced left-to-right shunt. Cathet Cardiovasc Diagn ; Failure to achieve this “Y” pattern of both disks requires device repositioning before release because this could lead to laceration of comunocacion aortic wall. The potential of paradoxical embolus may be assessed by increasing right sided pressures with the Valsalva maneuver.

It is critical to recognize the nomenclature and understand the anatomical disposition of the rims or edges bordering the ASD Figure 2. The presence of multiple defects of the inter-atrial septum have been reported in 7. Can J Interaurcular ; The diameter of the indentation can also be measured with fuoroscopy Figure 12 using calibration markers on the balloon catheter. Congenit Heart Dis ;5: Conclusions Percutaneous closure of significant shunting associated with secundum ASD represents an attractive less-invasive alternative therapy to surgery and is being increasingly performed worldwide.

SBDs by both methods are compared and measurements are repeated if there is a greater than 1 mm discrepancy.

A thorough evaluation comuniccaion presence of residual shunts is performed for future correlation. Nearby structures might be compromised after positioning of the occluder device.

J Am Coll Cardiol ; Device preparation for delivery is an important process of PTC and requires a meticulous approach on behalf of the interventional cardiologist Figure Transcatheter ASD closure is followed by near normalization of heart structure and function. The mid-esophageal bi-caval view provides an excellent view of the inter-atrial septum, allowing interrogation of the septum with CD. The ideal image is that of a figure “8” see below. Abnormal septal motion of the inter-ventricular septum is expected to normalize shortly after the procedure.

When a large Eustachian valve EV or Chiari network is present, it should be mentioned to the operator because it can cause device entrapment during deployment of the right atrial disk. The Minnesota maneuver or wiggle is performed prior to release, to ensure stability of the occluder device.

A major concern in the presence of two separate septal defects Figure 10 is the possibility of missing other supplementary defects. If such a mechanism is suspected, temporary balloon occlusion of the defect should permit its unmasking.

  LIBRO SISTEMAS OPERATIVOS WILLIAM STALLINGS PDF

J Invasive Cardiol ; Implications for surgical treatment. The first case in Mexico. Special considerations In older patients, left diastolic ventricular dysfunction associated with elevated flling pressures is observed and may lead to secondary pulmonary hypertension.

The amount of contrast needed to infate the balloon to this diameter is carefully recorded and the balloon is then completely defated and withdrawn from the patient. Long-term follow up of secundum atrial septal defect closure with the amplatzer septal occluder.

There was a problem providing the content you requested

Left ventricular conditioning in the elderly patient to prevent congestive heart failure after transcatheter closure of atrial septal defect. Absent posteroinferior and anterosuperior atrial septal defect rims: The ideal scenario for PTC is a single ASD with a maximal diameter of less than 20 mm, 8 with firm and adequately sized rims.

Received on February 1, ; Accepted on October 3, Afterwards, it is re-infated to the SBD volume and measured against a sizing plate. The role of echocardiography during interventional procedures is well documented 3,4 and several techniques have been described for the guidance of PTC of ASD. The use of aspirin 48 hours prior the procedure and for at least six months after the procedure is recommended, as interauriuclar as antibiotic prophylaxis 7 for six months after the procedure.

The reversal of RV volume overload has been shown as early as 3 weeks post procedure in children and 9 months in adults, 28 also systolic pulmonary artery pressure dropped to near normal levels during the following few months. Eur Heart J ; Mitral valve leafets might be encroached by the occluder device, producing mitral regurgitation in a defect with a defcient AV rim and, infow from the SVC and RUPV might be compromised in a defect with a defcient SVC rim.