LUGEON TEST PDF

LUGEON TEST PDF

Permeability test is necessary on terrain where are predicted soakaways which store water after big rainfall and provide efficient soil infiltration. A Lugeon is a unit devised to quantify the water permeability of bedrock and the hydraulic conductivity resulting from fractures; it is named after Maurice Lugeon, a Swiss geologist who first formulated the method in More specifically, the Lugeon test is used to measure the amount of water. Steady flow and its applications. ▫. Theim equation. ▫ Specific Capacity. ▫. Falling Head Test. ▫. Packer test. ▫ Wire line packer. ▫. Lugeon Test. ▫. Flow Log. ▫.

Author: Nitilar Tojajinn
Country: Namibia
Language: English (Spanish)
Genre: Science
Published (Last): 17 May 2016
Pages: 238
PDF File Size: 4.3 Mb
ePub File Size: 8.72 Mb
ISBN: 922-1-24885-988-1
Downloads: 78481
Price: Free* [*Free Regsitration Required]
Uploader: Mikanris

Considering a homogenous and isotropic condition, one Lugeon will be equal to 1. Typical range of Lugeon values and the corresponding rock condition is indicated in the table below.

And in rock mass the situation is even more complex. Usually they are used in areas where surface run-off cannot be disposed into existing sewers or watercourses. Reconstruction and conversion of a former Croatian post office building in Rijeka Gabion walls Georadar How to determine number and depth of exploration boreholes?

Luyeon, on a certain section of borehole, there are installed packers through which a special pipe brings water under pressure. In the enterence of the borehole pressure is measured lugen the pressure gauge, and the flow is measured with the watermeter.

If you have any questions, bee free to contact us! We assume no liability or responsibility for any errors or omissions in the content of this Lugeon Test calculator or such. We disclaim all warranties. If we want to infiltrate rainfall water at certain location, it is very important to know how much is the soil permeable. Free quote for buying Lugeon test equipment: The test is carried out at five stages including increasing and decreasing pressure between zero and maximum pressure. Water pressure and flow rate lugson measured everz minute.

  LUMINITA MON AMOUR PDF

At each step, a constant water pressure is applied for a duration of 10 minutes. The Lugeon test is an in- situ testing method widely used to estimate the average hydraulic conductivity in rock mass. The output is the maximum or average Lugeon Value.

This is an online Lugeon Test calculator. The waterflow which passing through the rock mass depends of some parameters such as: Therefore, the Lugeon value could represent not only the conductivity but also the rock jointing condition.

Range of Lugeon values and the corresponding rock condition. The water is injected into tfst isolated portion of the borehole using a slotted pipe which it self is bounded by the inflated packers. Using the average values of water presure and flow rate measured at each stage, the average hydraulic conductivity of the rock mass can be determined.

Lugeon test, complete online calculator – DAT instruments

It is useful to calculate Lugeon Value in permeability luyeon, given water pressure in bar, MegaPascal or PSIwater volume in literstest duration in minutes and length of borehole test interval in meters. Coefficient of permeability of the rock mass. Pricing information and quote request on Geotechgate. Using the average values of water pressure and flow rate measured in each stage, the average hydraulic conductivity of the rock mass is expressed in terms of Luheon unit.

First of all, a maximum test pressure Pmax is defined so that it does not exceed the in-situ minimum stress, thus avoiding hzdraulic fracturing. Use of this website is at your own risk.

Lugeon test, complete online calculator

Permeability test — the results. Open pit protection — Roxanich Heritage Wine Hotel teest wine cellar How to build on unstable terrains and avoid landslides? Typical range of Lugeon values and the corresponding rock condition is indicated in th etable below [1]. Open pit protection for Hotel Sensatori in Dubrovnik — reinforced concrete piles and strand anchors Why the Tower of Pisa commence lugeoh lean?

  CANCION DE CUNA LEO BROUWER PARTITURA PDF

It is indeed In situ test of formation permeability performed by measuring lugeob volume of water taken in a section of test hole when the interval is pressurized at given pressure 10 bars psi.

Accuracy of Information While we make reasonable efforts to give accurate and up-to-date information, we do not warrant that any information contained in or made available through this calculator is accurate, complete, reliable, current or error-free.

Lugeon value could also ougeon the rock jointing conditions, considering a big influence of rock discontinuities condition on value of hydraulic condutivity.

Following the empiricl original definition of the test, the hzdraulic conductiviy is experessed in terms of Lugeon Unit, being the conductivity required for a flow aret of 1 liter per minute per meter of the borehole interval under a constant pressure of 1 MPa.

Test is typically conducted in five steps.

Permeability test – Lugeon test

Send us an email to editor geotechdata. It is used primarily in variably permeable formations under evaluation of lygeon. Automatic Lugeon Tests recorder. The Lugeon Value is defined as the loss of water in liters per minute and per meter borehole at a pressure of 10 bar. Can you edit this page? Copyright – Geotechdata. The test is named after Maurice Lugeona Swiss geologist who first formulated the test.

Lugeon – Wikipedia

Lugeon test — stage. Table of porosity and water permeability of certain rocks and soil. At each stage, a constant pressure is applied for an interval of 10 miniutes while pumping water.